| Model UCL-IHP100 Inset Attenuator
 100 Watts DC-4GHz
 
 
 
| Model Number | Frequency Range(GHz) | Attenuation Value & Accuracy(dB) |   Max VSWR |  
| 3,6, 10, 20,30,40 |  
|   UCL-IHP100 | DC-2 | ±0.7 | 1.25 |  
| DC-4 | ±1.0 | 1.40 |  
 
 ※ Inset attenuators are used in absorbing energy of transmission line, expanding power range and controlling power level, they are also used in accurately measuring power or spectrum of RF microwave transmitters accompany with small power meter, comprehensive tester or spectrum analyzer. UCL-IHP100 serial Inset attenuators' average power from 50W-300W, frequency range from DC-4GHz.
 ※ NOMINAL IMPEDANCE: 50Ω                           AVERAGE POWER: 100W average to 25°C ambient
 temperature, derated linearly to 10W @ 125°C.
 PEAK POWER: 5KW (5μs pulse width with 2% duty cycle)
 3rd  ORDER INTERMODULATION(Optional):
 Reflected Levels(IM3) <-100dBc with two input signals
 @935MHz and 960MHz with average carrier power levels of
 +43dBm each.
 TEMPERATURE RANGE: -55°C~+125°C
 CONNECTOR TYPE: N,SMA
 WEIGHT: 0.35Kg
 PHYSICAL DIMENSIONS: 131×50×26mm
 
 
  1-69 UCL-IHP100.PDF 
 
 |