Model UCL-HP100G(F) Coaxial Fixed Attenuator 100 Watts DC-18GHz
Model Number |
Frequency
Range (GHz) |
Attenuation Value & Accuracy (dB) |
Max
VSWR |
10 |
20 |
30 |
40 |
UCL-HP100G(F)-4 |
DC-4 |
-0.5/+1.0 |
-0.5/+0.8 |
±0.7 |
±0.7 |
1.20 |
UCL-HP100G(F)-8 |
DC-8 |
-0.5/+1.5 |
-0.5/+1.2 |
±0.85 |
±0.85 |
1.35 |
UCL-HP100G(F)-12.4 |
DC-12.4 |
-0.5/+2.5 |
-0.5/+2.0 |
±1.20 |
±1.20 |
1.40 |
UCL-HP100G(F)-18 |
DC-18 |
-0.5/+3.6 |
-0.5/+3.0 |
-1.0/+2.5 |
-1.0/+2.5 |
1.50 |
※ Coaxial fixed attenuators are used in absorbing energy of transmission line, expanding power range and controlling power level, they are also used in accurately measuring power or spectrum of RF microwave transmitters accompany with small power meter, comprehensive tester or spectrum analyzer. UCL-HP100G(F)serial coaxial fixed attenuators' average power 1W-10KW, frequency range DC-18GHz and feature wide frequency band, low VSWR, flatness at, , , tenuation value, excellent capacity in anti-pulse and anti-burnout.
※ NOMINAL IMPEDANCE: 50Ω AVERAGE POWER: 100W average to 25°C ambient temperature, derated linearly to 10W @ 125°C. PEAK POWER: 1KW (5μs pulse width with 10% duty cycle) 3rd ORDER INTERMODULATION(Optional): Reflected Levels(IM3) <-100dBc with two input signals @935MHz and 960MHz with average carrier power levels of +43dBm each. TEMPERATURE RANGE: -55°C~+125°C CONNECTOR TYPE: N, SMA WEIGHT: A: 0.75Kg; B: 1.42Kg PHYSICAL DIMENSIONS: A: Φ45×240mm; B: 240×90×130mm(with fans)
1-36 UCL-HP100G(F).PDF
|